Trailer braking systemsChennai · Jaipur · India & export markets
sales@trailercontrolsystems.comPartner portal ↗
Product centrePneumatic Control
Technical product record

Relay Emergency Valve

Service-brake relay and emergency response when trailer supply is interrupted.

TCS part number9001302930
Portfolio familyPneumatic Control
System role

Transmit brake demand rapidly and manage supply-line failure response.

Typical application

Conventional air-brake trailer circuits.

Reference specification

Known product data.

Values shown are portfolio references for enquiry preparation. Confirm the released specification, variant and interfaces before ordering.

MediumCompressed air
FunctionService relay and emergency control
PortsConfirm circuit and thread arrangement
System context

Where this product sits in the control chain.

Route, relay, limit, isolate or exhaust compressed air so the intended trailer function occurs with the required response.

Upstream inputs

Supply reservoir pressure, service or parking control signal and circuit protection devices.

Selected recordRelay Emergency ValveTransmit brake demand rapidly and manage supply-line failure response.
Downstream effect

Controlled delivery pressure to chambers, auxiliary valves or protected pneumatic branches.

Application decision record

What must be confirmed.

The review separates selection, installation and field evidence so responsibility and open points remain clear.

01

Selection inputs

  • Exact valve function and behaviour during supply loss
  • Port numbering, thread family, size and flow direction
  • Operating-pressure range and any fixed or adjustable setting
  • Mounting orientation, exhaust path and response requirement
02

Installation review

  • Match every circuit line to the marked port—not physical position alone
  • Prevent sealant, swarf, moisture and line contamination
  • Keep exhaust openings clear and protected from direct spray
  • Leak-test the complete circuit in every operating state
03

Service evidence

  • Supply, control and delivery pressure readings
  • Leak location and operating state when leakage occurs
  • Application and release timing observation
  • Port map, installed orientation and current part label
Verification focus

Four checks that deserve an explicit record.

01Port logic
02Leakage
03Crack or limiting pressure
04Emergency response
Discuss this record

Relay Emergency Valve
9001302930

Share the trailer, operating duty, current part evidence, quantity and destination. The applications team will identify remaining technical questions before quotation.

Request an application review